Mitsubishi Electric MELSEC-LD77MS2 User Manual page 941

Hide thumbs Also See for MELSEC-LD77MS2:
Table of Contents

Advertisement

Related buffer memory address
LD77MS2
LD77MS16
LD77MS4
30103+200n
28403+100n
54000+20k
54002+20k
54003+20k
54004+20k
54005+20k
JOG speed
1518+100n
4318+100n
1519+100n
4319+100n
New speed value
1514+100n
4314+100n
1515+100n
4315+100n
JOG speed limit value
48+150n
49+150n
Positioning operation speed override
1513+100n
4313+100n
1522+100n
4322+100n
1523+100n
4323+100n
Set range
(Setting with sequence program)
<Servo parameter "Absolute
position detection system (PA03)">
0, 1
< Mark detection signal setting >
0 to 16
< Mark detection data type >
-1 to 12
< Mark detection data axis No.>
1 to 16, 801 to 804
<Mark detection data buffer memory No.>
0 to 65534
<JOG speed>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min or another]
<New speed value>
0 to 1000000000 [PLS/s]
-2
0 to 2000000000 [ 10
mm/min or another]
<JOG speed limit value>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min or another]
< Positioning operation speed override >
1 to 300 [%]
<Manual pulse generator 1 pulse input
magnification>
1 to 1000
16 - 57
Chapter 16 Troubleshooting
Remedy
Match the setting of the servo parameter "Absolute
position detection system (PA03)" to the setting of VCII
series, and turn the PLC READY signal [Y0] from OFF
to ON.
Set a value within the setting range.
Set a value within the setting range.
Set a value with an even number within the setting
range.
Do not carry out the JOG speed change during
deceleration with the JOG start signal OFF.
Set a value within the setting range.
Set the manual pulse generator 1 pulse input
magnification to within the setting range.
n: Axis No.-1
k: Mark detection setting No.-1