[2] Setting method of "Speed control 10 x multiplier setting for degree
axis function"
Set "Valid/Invalid" by "
Normally, the speed specification range is 0.001 to 2000000.000[degree/min],
but it will be decupled and become 0.01 to 20000000.00[degree/min] by setting
"
Pr.83
To use the "Speed control 10 x multiplier setting for degree axis function", set the
parameters shown in the following table.
Setting item
Speed control 10
x multiplier setting
Pr.83
for degree axis
: Refer to Section 5.2.4 "Detailed parameters 2" for details on the setting details.
Pr.83
Speed control 10 x multiplier setting for degree axis
Setting
value
Set the speed control 10 x multiplier setting for
degree axis.
0: Invalid
1: Valid
13 - 102
Chapter 13 Control Sub Functions
Speed control 10 x multiplier setting for degree axis
Setting details
" to valid.
Buffer memory address
LD77MS2
LD77MS16
LD77MS4
63+150n
n: Axis No.-1
".