Standard Parameters - Mitsubishi Electric 800 Series Instruction Manual

Plug-in option, profibus-dp communication function
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

7.7

Standard parameters

You can use the PNU to make parameter settings from the network.
The table below lists PNU numbers corresponding to parameter numbers.
Standard parameter examples are introduced below. Refer to the examples and make parameter settings.
For the parameter details, refer to the FR-E800 Instruction Manual (Function).
Representation of the PNU for standard parameters (Example: Pr.902)
P1902.1
Sub-Index Number
1000 + Parameter Number
• Example of parameter list
PNU
Bit 0 of the ext-index number = "0"
P1000
Pr.0 Torque boost
P1001
Pr.1 Maximum frequency
P1002
Pr.2 Minimum frequency
P1003
Pr.3 Base frequency
P1004
Pr.4 Multi-speed setting (high speed)
P1005
Pr.5 Multi-speed setting (middle speed)
P1006
Pr.6 Multi-speed setting (low speed)
.
.
.
.
.
.
Name
Bit 0 of the ext-index number = "1"
Pr.1000
Pr.1001
Pr.1002 Lq tuning target current adjustment
coefficient
Pr.1003
Pr.1004
Pr.1005
Pr.1006 Clock (year)
.
.
.
PPO TYPE SUPPORT SPECIFICATION
Data type
Us16
Us16
Us16
Us16
Us16
Us16
Us16
.
.
.
59