20cm(7.87inch) to
30cm(11.82inch)
Using the AD75CK, you can tie four cables of about 7mm (0.28inch) outside diameter
together for grounding.
(Refer to the "AD75CK-type Cable Clamping Instruction Manual" (IB-68682).)
Do not ground the cable clamp to the top of control panel. Doing so may lead to damage by
damage of screws, etc. during installation or removing the cable clamp.
Chapter 4 Installation, Wiring and Maintenance of the Product
(6) To make this product conform to the EMC directive instruction and Low
Voltage Directives, be sure to use an AD75CK type cable clamp
(manufactured by Mitsubishi Electric) for grounding connected to the control
box and the shielded cable.
LD77MS
AD75CK
[How to ground shielded cable using AD75CK]
Shielded cable
Shield
CAUTION
Inside control box
Ground terminal installation screw (M4 8 screw)
Installation screw to control box (M4 screw)
4 - 14
Ground terminal