Data Required For Major Positioning Control - Mitsubishi Electric MELSEC-LD77MS2 User Manual

Hide thumbs Also See for MELSEC-LD77MS2:
Table of Contents

Advertisement

9.1.1 Data required for major positioning control

Setting item
Da.1 Operation pattern
Da.2 Control method
Da.3 Acceleration time No.
Da.4 Deceleration time No.
Axis to be interpolated
Da.5
LD77MS2
Positioning address/
Da.6
movement amount
Da.7 Arc address
Da.8 Command speed
Dwell time/JUMP
destination
Da.9
positioning data No.
M code/Condition
data No./Number of
Da.10
LOOP to LEND
repetitions
Axis to be interpolated
Da.20
No.1
LD77MS16
Axis to be interpolated
Da.21
No.2
LD77MS16
Axis to be interpolated
Da.22
No.3
LD77MS16
(Note): The settings and setting requirement for the setting details of
according to the "
The following table shows an outline of the "positioning data" configuration and setting
details required to carry out the "major positioning controls".
Set the method by which the continuous positioning data (Ex: positioning data No.1,
No.2, No.3) will be controlled. (Refer to Section 9.1.2.)
Set the control method defined as a "major positioning control". (Refer to Section 9.1.)
Select and set the acceleration time at control start. (Select one of the four values set
in
,
Pr.9
Pr.25
Select and set the deceleration time at control stop. (Select one of the four values set
in
,
Pr.10
Set an axis to be interpolated (partner axis) during the 2-axis interpolation operation
(Refer to Section 9.1.6.).
LD77MS4
Set the target value during position control. (Refer to Section 9.1.3.)
Set the sub point or center point address during circular interpolation control.
Set the speed during the control execution.
The time between the command pulse output is completed to the positioning
completed signal is turned ON. Set it for absorbing the delay of the mechanical system
to the instruction, such as the delay of the servo system (deviation).
Set this item when carrying out sub work (clamp and drill stops, tool replacement, etc.)
corresponding to the code No. related to the positioning data execution.
Set an axis to be interpolated during the 2- to 4-axis interpolation operation.
(Refer to Section 9.1.6.)
Control method". (Refer to Section 9.2 "Setting the positioning data".)
Da.2
Major positioning control sub functions
Refer to Section 3.2.5 "Combination of LD77MS main functions and sub functions"
for details on "sub functions" that can be combined with the major positioning
control.
Also refer to Chapter 13 "Control Sub Functions" for details on each sub function.
Major positioning control from GX Works2
"Major positioning control" can be executed by test function of GX Works2.
Refer to "Simple Motion Module Setting Tool Help" of GX Works2 for details on
carrying out major positioning control from the GX Works2.
REMARK
600 positioning data (positioning data No. 1 to 600) items can be set per axis.
,
, and
Pr.26
Pr.27
,
, and
Pr.28
Pr.29
Pr.30
Da.1
9 - 4
Chapter 9 Major Positioning Control
Setting details
for the acceleration time.)
for the deceleration time.)
to
and
Da.10
Da.20
to
differ
Da.22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l seriesMelsec-ld77ms4Melsec-ld77ms16