Mitsubishi Electric MELSEC-LD77MS2 User Manual page 921

Hide thumbs Also See for MELSEC-LD77MS2:
Table of Contents

Advertisement

Related buffer memory address
LD77MS2
LD77MS16
LD77MS4
1+150n
6+150n
7+150n
Unit magnification
1+150n
Number of pulses per rotation
2+150n
3+150n
Movement amount per rotation
4+150n
5+150n
10+150n
11+150n
12+150n
13+150n
14+150n
15+150n
17+150n
18+150n
19+150n
20+150n
21+150n
Set range
(Setting with sequence program)
1,10,100,1000
0 [PLS/s]
-2
0 [ 10
mm/min or others]
0.001 ≤ Electronic gear ≤ 320000
Pr.2
Electronic gear =
×
Pr.3
Pr.4
<Speed limit value>
1 to 1000000000 [PLS/s]
-2
1 to 2000000000 [ 10
mm/min or others]
1 to 8388608
1 to 8388608
×
Pr.11
Pr.2
0 ≤
≤ 4194303
×
Pr.3
Pr.4
• [mm] [inch] [PLS]
–2147483648 to 2147483647
• [degree] 0 to 35999999
• [mm] [inch] [PLS]
–2147483648 to 2147483647
• [degree] 0 to 35999999
16 - 37
Chapter 16 Troubleshooting
Remedy
• Set AL and AM values which make "Movement amount per
rotation (AL)" × "Unit magnification (AM)" within 2147483647,
and then turn the PLC READY signal [Y0] from OFF to ON.
• With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
• Set the bias speed to not more than the speed limit value.
• With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
"
Number of pulses per rotation (AP)
Pr.2
"
Movement amount per rotation (AL)
Pr.3
"
"
Unit magnification (AM)
Pr.4
Review these parameters.
(Refer to Section 5.2.1)
• Set a value which is not less than the OPR speed.
• With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
"
Number of pulses per rotation (AP)
Pr.2
"
Movement amount per rotation (AL)
Pr.3
"
"
Unit magnification (AM)
Pr.4
"
Backlash compensation amount
Pr.11
Review the items above.
(Refer to Section 5.2.1 or Section 5.2.3)
• Bring the setting into the setting range.
• In a unit other than "degree", set so that the lower limit value
is smaller than the upper limit value.
",
",
",
",
"
n: Axis No.-1