Goodrive300-01A series VFD for air compressor
Function
Name
code
P19.15
Device state
Accumulated running
P19.16
Accumulated
P19.17
load-carrying running
P19.18
Restart count-down
1: Maintenance required; 0: Normal
BIT5: Auxiliary pressure signal
1: Auxiliary pressure signal fault; 0: Normal
BIT6: Auxiliary temperature signal
1: Auxiliary temperature signal fault; 0: Normal
BIT7: Auxiliary pressure pre-alarm signal
1: Pressure pre-alarm; 0: Normal
BIT8: Auxiliary temperature pre-alarm signal
1: Temperature pre-alarm; 0: Normal
BIT9: Auxiliary pressure alarm signal
1: Pressure alarm; 0: Normal
BIT10: Auxiliary temperature alarm signal
1: Temperature alarm; 0: Normal
BIT11: Maintenance timeout remainder
1: Maintenance timeout remainder; 0: Normal
BIT12: Phase sequence remainder
1: Fault; 0: Normal
0: Standby
1: Run
2: Fault
3: Emergency stop
4: Undervoltage
5: Alarm
6: Sleep
7: In stop
8: Restart delay
time
Display range: 0–65535h
time
Display the remaining time of restart delay
(P18.16). After the system stops, it will enter
restart delay state and restart count-down to
prevent immediate restart. After restart delay
time is up, the system enters standby state.
Under standby state, start command can be
received.
Setting range: 0–3600s
Description
-76-
Function code description
Default Modify
●
0
●
0
●
0
●
0s
Need help?
Do you have a question about the Goodrive300-01A Series and is the answer not in the manual?
Questions and answers