Goodrive300-01A series VFD for air compressor
Function
description
VFD state word 1
VFD state word 2
VFD fault code
VFD identification
code
Address
definition
The set maintenance time of part 1;
2010H
Range: 0–65535
The set maintenance time of part 2;
2011H
Range: 0–65535
The set maintenance time of part 3;
2012H
Range: 0–65535
The set maintenance time of part 4;
2013H
Range: 0–65535
The set maintenance time of part 5;
2014H
Range: 0–65535
2015H
Running time of part 1, 0–65535
2016H
Running time of part 2, 0–65535
2017H
Running time of part 3, 0–65535
2018H
Running time of part 4, 0–65535
2019H
Running time of part 5, 0–65535
201AH
Running time of the device: 0–65535
Start/stop command of power-frequency fan,
201BH
0–3
0001H: In forward running
0002H: In reverse running
0003H: In stopping
2100H
0004H: In fault
0005H: VFD Poff state
0006H: VFD pre-exciting state
Bit0: =0: Not ready to run =1: Ready to run
Bi1–2: =00: Motor 1
Bit3: =0: Asynchronous motor
=1: Synchronous motor
2101H
Bit4: =0: Non-overload pre-alarm
=1: Overload pre-alarm
Bit5– Bit6:
=00: Keypad control
=01: Terminal control
=10: communication control
2102H
See fault type
2103H
GD300-01A-----0x012F
Data meaning
=01: Motor 2
=10: Motor 3
=11: Motor 4
-162-
Communication protocol
R/W
attribute
W
W
W
W
W
W
W
W
W
W
W
W
R
R
R
R