Goodrive300-01A series VFD for air compressor
B.1.4.8 Protection parameter interface
1. Enter the protection parameter interface through the main menu.
Protection
parameter
Prealarm
temperature
Alarm
temperature
03.17 16:02:35
Current value
Return
Figure B-24 Accumulative oil filter use time
03.17 16:02:35
Prealarm Pressure
Alarm Pressure
Prealarm Temp
Alarm Temp
Low Temp Protect Thred xxxxxx
Auxiliary Press Protection Invalid
Return
03.17 16:02:35
Auxiliary Press Prealarm
Auxiliary Press Alarm
Auxiliary Temp Proteciton
Present Auxiliary Temp
Auxiliary Temp Prealarm
Auxiliary Temp Alarm
Return
Figure B-25 Protection parameter interface
Initial value
When the actual exhaust temperature is higher than this
105° C
temperature, a pre-alarm is reported.
When the actual exhaust temperature is higher than this
110° C
temperature, an alarm is reported, and the device is stopped.
Oil filter run time
xxxxx
h
Home
Protection param
xxx.xx MPa
xxx.xx Mpa
xxxxxx
xxxxxx
Home
Protection param
xxx.xx MPa
xxx.xx MPa
Invalid
xxxxxx
xxxxxx
xxxxxx
Home
Function
-123-
External optional accessories
Clear
Edit
Edit