Goodrive300-01A series VFD for air compressor
P08 group Enhanced functions
Function
Name
code
Bus voltage
P08.15
pre-protection function
Low-voltage protection
P08.16
threshold
Overvoltage
P08.17
pre-protection
threshold
P08.18 Automatic restart delay 0.0–6000.0s
Low-voltage frequency
P08.19
limit running time
High-frequency current
P08.20
loop proportional gain
High-frequency current
P08.21
loop integral time
High-frequency current
P08.23
loop switching
frequency
Fan control enable
P08.24
selection
P08.25
Keypad lock enable
Maintenance timing
P08.26
SM optimal mode
P08.27
selection
0–0x11Ones: Bus protection function
Tens: Low-frequency current protection
function
0.0V–2000.0V
0.0V–2000.0V
0.0–6000.0s
0–20000
0–20000
0.0–100.0% (max. output frequency P00.03)
0–1
0: Enable fan control
1: Disable fan control
Note: Applicable to 7.5–15kW single-VFD
integrated machine only, used to control the
start/stop of a power-frequency fan.
0: Do not lock keypad
1: Allow to lock keypad
Lock: Press PRG key+DATA key
simultaneously
Unlock: Keep DATA key pressed down and
then click V key by three times.
0: No timing during sleep
mode
1: Timing during sleep
0: Disable
It is applicable to the surface-mounted
synchronous motors. P02.21 (Direct-axis
inductance
(Quadrature-axis inductance of SM 1) are
Description
of
SM
1)
and
-51-
Function code description
Default Modify
0x10
300.0V
780.0V
60.0s
60.0s
1000
1000
100.0%
0
0
0
0
P02.22
○
○
○
○
○
○
○
○
○
○
○
○
Need help?
Do you have a question about the Goodrive300-01A Series and is the answer not in the manual?
Questions and answers