Goodrive300-01A series VFD for air compressor
Function
Name
code
P08.28
Auto fault reset count During the automatic reset period, the fault
Auto fault reset interval
P08.29
setting
Frequency decrease
P08.30
ratio in drop control
FDT1 electrical level
P08.32
detection value
FDT1 lagging
P08.33
detection value
FDT2 electrical level
P08.34
detection value
FDT2 lagging
P08.35
detection value
Detection value for
P08.36
frequency being
reached
Cooling fan running
P08.39
used in the calculation.
1: Enable
It is applicable to the embedded/
surface-mounted
P02.21 (Direct-axis inductance of SM 1) is
used in the calculation.
Note: You can disable or enable the
optimization mode according to the motor at
the scene.
will not be reported externally, only the keypad
TRIP indicator blinks, and P17.39 shows the
warning code. The automatic fault reset
function is enabled for these faults, such as
OUt1, OUt2, Out3, OL1, OL2, OH1, OH2, EF,
CE, ItE, tE, EEP, END, PCE, UPE, DNE,
ETH1, ETH2, PSF, etc. Fault codes will be
reported immediately when these types of
faults occur.
Setting range of P08.28: 0–10
Setting range of P08.29: 0.1–3600.0s
0.00–50.00Hz
0.00–P00.03 (max. output frequency)
-100.0–100.0% (FDT1 electrical level)
0.00–P00.03 (max. output frequency)
-100.0–100.0% (FDT2 electrical level)
0.0–P00.03 (max. output frequency)
0: Common running mode: Do not run during
sleep.
1: The fan
mode
powered on
2: Temperature control: The fan turns on when
Description
synchronous
keeps running after being
-52-
Function code description
Default Modify
motors.
5
5.0
0.00Hz
50.00Hz
5.0%
50.00Hz
5.0%
0.00Hz
0
○
○
○
○
○
○
○
○
○