IP Telephone - Response Busy
If the response is Busy:
1. Is the telephone engaged in a call? If it is wait for the call to
finish and check again for dial tone.
2. If the telephone is not on a call try resetting the handset.
IP Telephone - Response Idle
If the response is Idle
Reset the telephone.
IP Telephone - Response Manbusy
If the response is Manbusy
1. Find out why it is Manbusy.
2. Return to Service using the RTS <location ID>command.
IP Telephone - Response Out of Service
If the response is Out of Service:
1. Check the phone has power (does it have a display).
2. If the phone does not have power then connect to an
appropriate power source.
3. If the phone does have power then verify the link integrity LEDs.
A green LED on the bottom of the phone indicates a proper
connection. A flashing yellow LED indicates activity (data flow)
on the network.
4. If the LEDs are not showing check the wiring.
5. If the phone has power and the LEDs are on then refer to the IP
phone diagnostics.

If the IP Telephone Fails to Boot

1. Verify the Network Connection.
2. Verify power (is there a display?).
3. Check the wiring.