3300 ICP Technician's Handbook – Release 3.2

Install the 3300 R2 NSU

To install and configure the 3300 R2 NSU:
1. Set the DIP switches for the protocol and site installation. The
default configuration of the DIP switches will support T1
protocols in network termination mode.
2. Establish a fiber connection from the fiber port on the NSU to
the fiber port on the 3300 Controller.
3. Connect the NSU L0 and/or L1 port to the remote system (the
PSTN or another system).
4. Install a Direct Connection Device Driver on a PC. Refer to
Install the 3300 Universal NSU for details.
5. Create a Dial-up Network connection on the PC. Refer to Install
the 3300 Universal NSU for details.
6. Connect the computer to the 3300 R2 NSU.
7. Use the IMAT Tool to complete the required configuration.
8. Connect the 3300 R2 NSU to the PSTN network.
9. Connect the 3300 R2 NSU to the 3300 Controller.
10. Connect power to the NSU.
Connections
Connect the computer to the 3300 R2 NSU
To connect the computer to the 3300 R2 NSU:
1. Connect the serial cable from the computer's COM port to the
3300 R2 NSU 9-pin serial port.
2. On the File menu, click Connect to Remote Site.
3. In the Dial-Up Entry box, select the <name> you entered for
the connection when creating the dial-up connection. (See Dial-
Up Networking Connection.) Note: The 3300 R2 NSU does not
require a password.
4. Ensure that PRI CARD is selected under Remote ISDN
System.
- 27 -