Note: Type the IP address and subnet mask (in hexadecimal
format for the end user's site (i.e. ffffff represents
255.255.255.00).
inet on backplane (b):
host inet (h):
gateway inet (g): 134.199.63.251 (example Router (Gateway)
address)
Note: Enter the IP address of the end user's gateway for the
3300 Controller.
user (u): ftp
ftp password: @
flags (f): 0x0 (a fixed IP address (0x40 is used on E2T for
DHCP))
target name (tn):
startup script (s):
other (o): motfcc (other device, E2T using Network to boot from)
5. Insert the software CD-ROM into the CD drive of the installer's
PC.
6. Run the "Setup.exe" program from the CD.
7. Select Upgrade Installation.
8. Choose a location for the Setup program to install files (default
is C:\MN3300).
9. Type in the IP address of the RTC.
10. Enter the username and password to Log into the FTP Server
(by default the username is ftp and the password is @). The
installSetup program:
- Provides a progress indicator and log file
- Checks the disk space in the specified location
- Checks the country variant of existing software
- Puts files in the created directory under the chosen location.
Default location will result in: "c:3300 ICP\".
- Runs an FTP Client Session to load new software files to the
Install directory.
11. Review the Readme file.
12. Go to the cmd prompt (->) of the RTC shell.
- 91 -