3300 ICP Technician's Handbook – Release 3.2
5. Press the Reset button on the 3300 Controller with a small
pointed object.
6. Wait for the "Press any key to stop auto-boot" message and
then press a key.
7.
At VxWorks Boot type c and then press Enter.
Press Enter after you enter required text. For all other fields,
(displayed in grey
value or leave blank.
boot device: ata=0,0 (Boot device is Disk)
unit number: 0 (default, leave at 0, not used)
processor number: 0 (default, leave at 0, not used)
host name:
file name: /sysro/Rtc8260 (boot location and file name)
inet on ethernet (e): 134.199.63.11:ffffff00 (example RTC IP
and subnet mask)
Note: Type the IP address and subnet mask (in hexadecimal
format for the end user's site (i.e. ffffff represents
255.255.255.00).
inet on backplane (b):
host inet (h):
gateway inet (g): 134.199.63.251 (example Router (Gateway)
address)
Note: Enter the IP address of the end user's gateway for the
3300 Controller.
user (u): ftp (must be ftp for Release 3.1)
ftp password (ftp) (blank = @):
flags (f): 0x0 (a fixed IP address (0x40 is used on E2T for
DHCP)
target name (tn):
startup script (s):
other (o): motfcc (other device, E2T using Network to boot from)
8. Press the Reset button on the 3300 Controller.
9. Remove the Serial connection. The system will return to service
in about 10 to 15 minutes.
Note: It may be helpful to leave the serial connection in place to
capture any potential errors.