3300 ICP Technician's Handbook – Release 3.2
2. Check the connector pins to be certain that they are straight.
3. Slide the card into the slot.
4. Push the upper and lower latches away from you until they are
vertical and the card is locked in place.
5. To return the circuits to service, enter
BRI Installation Overview
Before you install the BRI card, ensure that:
The configuration includes a CEPT Formatter card that has an
unused hybrid circuit (one Rx/Tx pair) configured with DPNSS
protocol
The system has a free DSU slot for the BRI card
The wiring from the Network Termination Terminal Equipment
(NTTE), Network Termination 1 (NT1), or terminating
equipment is Cat 5 UTP
A computer is available for use as maintenance PC.
Installation Sequence
Install the BRI card in the following sequence:
Program the customer data in the 3300 ICP
Install the BRI interface assembly
Install the BRI card and make connections
Connect the terminal equipment.
Install a BRI Interface Assembly
To install the BRI interface assembly:
1. Attach the anti-static strap to your wrist.
2. Unpack the interface assembly and inspect it to ensure that it is
not damaged.
3. At the rear of the DSU cabinet, locate the slot in the DSU box
that corresponds to the slot in the system card frame that will be
used for the BRI card. The BRI card should be as close as
possible to its associated CEPT card.
RTS <PLID>.