Carrier Card, COV Line Card, 3DN, 4DN, SUPERSET 3,
SUPERSET 4, SUPERSET 700, SUPERSET 7DN,
SUPERCONSOLE 2000, and datasets).
2. Program SX-2000 connectivity using NE Editor.
3. Backup SX-2000 database (datasave) from the 3300
Configuration Tool. The Configuration Tool will convert the SX-
2000 database to a 3300 database.
4. Program 3300 ICP connectivity using NE editor with the Variant
as 3300 ICP.
5. Enable Options.
6. Perform a Restore of the SX-2000 converted database onto the
3300 ICP. An automatic validation operation occurs to
determine if the restore can proceed.
7. Reboot the 3300 ICP. Check the logs for any data restore
failures (see Note).
8. Change the 3300 ICP system name through the System
Administration Tool.
Note: After the Restore and Reboot, check the log file. In the
System Administration Tool, click Maintenance and
Diagnostics, select Maintenance Commands, and click All.
Type the following text in the Command line:
- 95 -
type *.dr.logfile_1