3300 ICP Technician's Handbook – Release 3.2
The new Release 3.2 chassis:
1. Remove the cover.
2. Install the DSP Modules (slots MMC3 and MMC4).
3. Install the Sys ID Module.
4. Install the Hard Drive.
5. Replace the cover.

SX-2000 LIGHT to 3300 ICP

To upgrade SX-2000 LIGHT hardware for 3300 control:
384 port Peripheral - main control replacement
DSU - main control replacement
Peripheral cards - DNIC Line, ONS CLASS, ONS Line,
LS/GS Trk, E&M Tie Trk, OPS Line, DID/Loop Tie
DSU cards - T1 (DS1) Formatter, CEPT Interface, ISDN
PRI, E1/T1 Dig Trk Formatter, E1 R2, 6CCT BRI, 15CCT
BRI
If existing capacity is greater than that of the 3300 ICP, the
conversion will fail. See the capacity table for the 3300 ICP.