3300 ICP Technician's Handbook – Release 3.2
4. Change the Variant to 3300 ICP and change the IP Address if
required.
5. Enable Options.
6. Perform a Restore of the SX-2000 converted database onto the
3300 ICP. An automatic validation operation occurs to
determine if the restore can proceed.
7. Reboot the 3300 ICP. Check the logs for any data restore
failures (see Note).
8. Change the 3300 ICP system name through the System
Administration Tool.
Tip: After the Restore and Reboot, check the log file. In the
System Administration Tool, click Maintenance and
Diagnostics, select Maintenance Commands, and click All.
Type the following text in the Command line:
and click Submit.

SX-2000 MICRO LIGHT to 3300 ICP

Only one 3300 ICP can be configured at a time; and only
one SX-2000 can be migrated to a 3300 ICP at a time.
Migration and Configuration cannot be performed in a
single task or session using the 3300 Configuration Tool.
After migration, configuration must be completed using the
System Administration Tool.
Data restoration automatically triggers data migration.
The MICRO LIGHT appears as 2 pair of NSUs and a
Peripheral Unit to the 3300 ICP.
If existing capacity is greater than that of the 3300 ICP, the
conversion will fail. See the capacity table for the 3300 ICP.
Windows 2000 users should clear the browser cache.
To transfer database from SX-2000 MICRO LIGHT to 3300 ICP:
1. Prepare the SX-2000 MICRO LIGHT for migration:
- reduce Peripheral and DSU nodes to a maximum of 4
- deprogram unsupported devices and cards (AC13, AC15,
SCDC, DID3, Advanced Tone Detector, ISDN Gateway, FIM
- 94 -
type *.dr.logfile_1