Integrated communications platform
Table of Contents

Advertisement

3300 ICP Technician's Handbook – Release 3.2
The CD-ROM containing the Mitel Networks 3300 ICP
software release deliverables
An Ethernet cable (RJ45) to connect from your PC to the
3300 ICP controller
A serial cable (9600,8n1) to connect from your PC to the
3300 ICP maintenance port.
Communication software such as HyperTerm or VT100
Console to communicate with the 3300 ICP through the
maintenance port.
Time: Total upgrade time is about 4 hours.
Tip: You will need the 3300 ICP IP address, username, and
password.
To perform a software upgrade:
1. Launch the communication program.
2. Establish a serial connection from the 3300 Configuration Tool
PC (or any PC equipped with a communications program) to
the Maintenance Port on the 3300 Controller.
3. Set the communication program parameters to the following:
Baud rate - 9600
Data bits - 8
Parity - None
Stop bits - 1
Flow control - None.
4.
Connect to the 3300 Real Time Complex (RTC) via the
maintenance port and type bootChange.
Press Enter after you enter required text. For all other fields,
(displayed in grey
value or leave blank.
boot device: ata=0,0 (Boot device is Disk)
unit number: 0 (default, leave at 0, not used)
processor number: 0 (default, leave at 0, not used)
host name: (optional)
file name: /sysro/Rtc8260 (boot location and file name)
inet on ethernet (e): 134.199.63.11:ffffff00 (example RTC IP
and subnet mask)
text, for information only) accept the default
- 90 -