2. Unpack the FIM. Inspect the FIM to ensure that it is not
damaged.
3. Remove the DSU node front door
- Pry open the two latches on the right hand side of the black
cover panel on the front door, and swing the cover panel off to
the left.
- Loosen the two screws under the black panel to release the
front door.
- Pull the top corners of the front door out and lift it off the lip at
the bottom front of the node.
4. Remove the DSU cards from the cabinet. Insert each circuit
card in a separate anti-static bag.
5. Slide the FIM into the bottom slot 1 or slot 6 until it connects
with the backplane firmly. Fasten the FIM in place with the two
screws provided or use the latch on the card guides. See FIM
and PRC Installation in the DSU Node.
6. Remove the anti-static strap from your wrist.
R2 Installation Overview
The following section describes how to install the R2 card and R2
interface assembly. You will need to program the R2 card into the
3300 ICP database to allocate links and trunks.
Install the R2 card in the following sequence:
Program the customer data in the 3300 ICP
Configure the card for Line Side or Trunk Side termination
Install the interface assembly
Install the R2 card
Configure the IMAT database
Connect the computer to the R2 card
Save the IMAT database onto the R2 card
Connect the R2 Card to the PSTN network
Configure for Line Side/Trunk Side Termination
To configure the R2 card for Line Side or Trunk side termination: