3300 ICP Technician's Handbook – Release 3.2
Off
Flashing
On
Message Link Controlled (Card status)
LED State
Green - On
Yellow - On
Red - On
Green and
Yellow - On
Green and Red
- On
Yellow and Red
- On
Green, Yellow
and Red - On
No LEDs
illuminated
Fiber Interface Module LEDs
FIM Upper LED
On
Off
Flashing
Note: When a remote MFC Status LED is off, check the local FIM Status LED.
If it is on then the fiber optic cable may be faulty.
3300 R2 NSU
To access the 3300 R2 NSU maintenance window:
No Power
Powered On, BSP Running
Communication Link synchronized with 3300
Controller
Meaning
no error
out of service
error - does not necessarily indicate total failure
out of service - this combination may occur at power-up
a fault has been detected
out of service - this combination appears at power-up
at power-up before fully operational
fully operational
Meaning for Local, upper and Remote, lower FIM
In frame synchronization
Power off or held in reset
Out of synchronization or Tx and Rx cables reversed
- 132 -