New Holland WorkMaster 50 Service Manual page 1029

Tier 4b (final)
Hide thumbs Also See for WorkMaster 50:
Table of Contents

Advertisement

DTC 2E1-03-Starter relay low side driver circuit shorted to battery . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 2E1-04-Starter relay low side driver circuit shorted to ground . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 2E1-12-Starter relay low side ECU driver circuit over temperature . . . . . . . . . . . . . . . . . . . . . . .
DTC 32B-02-Glow plug control circuits open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 32B-03-Glow plug control circuits shorted to battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 32B-04-Glow plug control circuits shorted to ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 32B-12-Glow plug control circuits shorted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 359-04-Fuel metering unit is shorted to ground at the low side . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 35A-03-Error in comparing energizing time to maximum value for injector in cylinder 2 . . . . .
DTC 35A-04-Error in comparing energizing time to minimum value for injector in cylinder 2 . . . . . .
DTC 35D-03-PMCat Inducement warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 37F-12-Missing adjustment value programming for injector in cylinder 3 . . . . . . . . . . . . . . . . . .
DTC 3C8-02-CAN communication failure between vehicle controller and ECU controller - TSC1_VE
message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3D4-02-ECU internal failure - ECU shutdown test failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3D4-03-ECU internal failure - Wrong set response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3D4-04-ECU internal failure - SPI errors during MoCSOP execution . . . . . . . . . . . . . . . . . . . . .
DTC 3D4-12-ECU internal failure - Loss of synchronization to MM from CPU . . . . . . . . . . . . . . . . . .
DTC 3E3-00-ECU internal failure - Fuel injection energizing time is not plausible . . . . . . . . . . . . . . .
DTC 3E3-01-ECU internal failure - Fuel injection energizing phase is not plausible . . . . . . . . . . . . .
DTC 3E3-02-Fuel injection correction has exceeded a minimum limit . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3E3-03-ECU internal failure - Injection quantity correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3E3-04-ECU internal failure - Rail pressure plausibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3E3-12-ECU internal failure - Torque request comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 3F6-03-DOC inlet temperature sensor voltage is higher than expected . . . . . . . . . . . . . . . . . . .
DTC 3F6-04-DOC inlet temperature sensor voltage is lower than expected . . . . . . . . . . . . . . . . . . . .
DTC 426-03-Level 2 Monitoring : Reported Overvoltage of Supply . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 426-04-Level 2 Monitoring : Reported Under Voltage of Supply . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 435-12-Rail pressure sensor value is intermittent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 455-03-High pressure pump fuel delivery quantity at low idle is too high . . . . . . . . . . . . . . . . . .
DTC 459-03-Fuel metering unit intermittent electrical connection failure . . . . . . . . . . . . . . . . . . . . . . .
DTC 45A-03-Error in comparing energizing time to maximum value for injector in cylinder 3 . . . . .
DTC 45A-04-Error in comparing energizing time to minimum value for injector in cylinder 3 . . . . . .
DTC 48D-02-Throttle valve actuator control circuit open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 48D-03-Throttle valve actuator control circuit over current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 48D-12-Throttle valve actuator control circuit over temperature . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 4D4-03-ECU internal failure - Overvoltage monitoring error . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 4D4-04-ECU internal failure - Undervoltage monitoring error . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 4E3-03-ECU internal failure - Post injection quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 4E3-04-Level 2 Monitoring : Diagnosis fault check to report the error to demand for an ICO
due to an error in the PoI2 shut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTC 4E3-12-Level 2 Monitoring : Diagnosis fault check to report the error to demand for an ICO
due to an error in the PoI3 efficiency factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47866583_ 02/12/2015
55.12 [55.DTC] / 308
184
186
188
190
192
194
196
198
200
201
202
203
204
206
207
208
209
210
211
212
213
214
215
216
218
220
221
222
224
225
227
228
229
231
233
235
236
237
238
239

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workmaster 60Workmaster 70

Table of Contents