Chapter 17 Specifications - Rigol MSO4000 Series User Manual

Digital oscilloscope
Hide thumbs Also See for MSO4000 Series:
Table of Contents

Advertisement

Chapter 17 Specifications

Chapter 17 Specifications
All the specifications are guaranteed except the parameters marked with "Typical"
and the oscilloscope needs to operate for more than 30 minutes under the specified
operation temperature.
Sample
Sample Mode
Real-time Sample
Rate
Peak Detect
Averaging
High Resolution
Minimum
Detectable Pulse
Width
Memory Depth
MSO4000/DS4000 User's Guide
800.544.2843
Real-time sample
Analog channel:
4.0 GSa/s (interweave); 2.0 Gsa/s (non-interweave)
Digital channel: 1.0 Gsa/s
Analog channel:
250 ps (interweave); 500 ps (non-interweave)
Digital channel: 1 ns
After all the channels finish N samples at the same time, N
can be 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096
or 8192
when ≥5 μs/div @ 4 GSa/s (or ≥10 μs/div @ 2 GSa/s):
12 bit resolution
Digital channel: 5 ns
Analog channel:
Auto, 14k pts, 140k pts, 1.4M pts, 14M pts and 140M pts
(interweave);
Auto, 7k pts, 70k pts, 700k pts, 7M pts and 70M pts
(non-interweave)
Digital channel: maximum 28M pts