17 Specifications
17 Specifications
All the specifications are guaranteed except the parameters marked with "Typical"
and the oscilloscope needs to operate for more than 30 minutes under the specified
operation temperature.
Sample
Sample Mode
Real Time Sample
Rate
Peak Detect
Averaging
High Resolution
Minimum
Detectable Pulse
Width
Memory Depth
MSO4000/DS4000 User's Guide
Real-time Sample
Analog channel: 4.0 GSa/s (single-channel), 2.0 Gsa/s
(dual-channel)
Digital channel: 1.0 Gsa/s
Analog channel: 250 ps (single-channel); 500 ps
(dual-channel)
Digital channel: 1 ns
After all the channels finish N samples at the same time, N
can be 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096
or 8192.
12 bits of resolution when ≥5 μs/div @ 4 GSa/s (or ≥10
μs/div @ 2 GSa/s).
Digital channel: 5 ns
Analog channel:
single-channel: Auto, 14k pts, 140k pts, 1.4M pts, 14M pts
and 140M pts are available
dual-channel: Auto, 7k pts, 70k pts, 700k pts, 7M pts and
70M pts are available
Digital channel: maximum 28M pts
RIGOL
17-1