Chapter 5 Trigger
MSO4000/DS4000 User's Guide
800.544.2843
You can make the following settings:
Press ID Setup to select "Random ID" or "Specific ID".
a.
When "Random ID" is selected, the ID data will not be used as the
trigger condition. When "Specific ID" is selected, press ID
Format to select "Standard" or "Expand"; press ID Data and
turn the multi-function knob
navigation knob to adjust the ID data at a relatively smaller step
or turn the outer knob of the navigation knob to adjust the ID data
at a relatively larger step. The range of the ID data is from 0 to
2047 (standard ID format) or from 0 to 536870911 (expanded ID
format).
Note: The larger the rotation amplitude of the outer knob of the
navigation knob is, the faster the variation of the value will be.
When you need to adjust the ID data within a relatively larger
range, this function can help you quickly finish the setting.
Press Byte Length and turn the multi-function knob
b.
the desired byte length. The range is from 1 to 8.
Press CurrentBit and turn the multi-function knob
c.
the data bit to be operated and the range is from 0 to (the current
"Byte Length"×8-1).
Press Data to set the data pattern of the current data bit to H, L or
d.
X. You can also switch the data pattern of the current data bit by
pressing the multi-function knob
the CurrentBit.
e.
Press AllBits to set the patterns of all the bits to the pattern of the
current data bit (namely the pattern in Data).
When "Remote" is selected, you can make the ID settings by referring
to step a above.
2) Frame Error:
When the trigger condition is set to "Frame Error", press Error Type and
turn the multi-function knob
www.calcert.com
15
10
20
5
25
0
30
or the inner knob of the
continuously after you set
to select the desired error type. You can
RIGOL
to select
to select
5-47