RIGOL
Input
Number of
Channels
Input Coupling
Input Impedance
Probe Attenuation
Coefficient
Maximum Input
Voltage (1 MΩ)
17-2
800.544.2843
MSO40X4: 4-analog-channel + 16-digital-channel
MSO40X2: dual-analog-channel + 16-digital-channel
DS40X4: 4-channel
DS40X2: dual-channel
DC, AC or GND
Analog channel: (1 MΩ±1%) || (15 pF±3 pF) or 50 Ω±1.5%
Digital channel: (101 kΩ±1%) || (9 pF±1 pF)
Analog channel: 0.01X to 1000X, in 1-2-5 step
Analog channel:
CAT I 300 Vrms, CAT II 100 Vrms, transient overvoltage
1000 Vpk
with RP2200 10:1 probe: CAT II 300 Vrms
with RP3300 10:1 probe: CAT II 300 Vrms
with RP3500 10:1 probe: CAT II 300 Vrms
with RP5600 10:1 probe: CAT II 300 Vrms
Digital channel:
CAT I 40 Vrms, transient overvoltage 800 Vpk
www.calcert.com
15
10
20
5
25
0
30
Chapter 17 Specifications
MSO4000/DS4000 User's Guide