Page 1
RIGOL Service Guide MSO1000Z/DS1000Z Series Digital Oscilloscope Nov. 2014 RIGOL Technologies, Inc.
Page 3
Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at company’s sole decision. Information in this publication replaces all previously corresponding material.
RIGOL Safety Requirement General Safety Summary Please review the following safety precautions carefully before putting the instrument into operation so as to avoid any personal injury or damage to the instrument and any product connected to it. To prevent potential hazards, please use the instrument only specified by this manual.
Page 5
RIGOL Do Not Operate With Suspected Failures. If you suspect damage occurs to the instrument, have it inspected by RIGOL authorized personnel before further operations. Any maintenance, adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel.
RIGOL Safety Terms and Symbols Terms Used in this Manual. These terms may appear in this manual: WARNING Warning statements indicate conditions or practices that could result in injury or loss of life. CAUTION Caution statements indicate conditions or practices that could result in damage to this product or other property.
RIGOL Allgemeine Sicherheits Informationen Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonenschädenoderSchäden am Gerätundan damit verbundenen weiteren Gerätenzu vermeiden. Zur Vermeidung vonGefahren, nutzen Sie bitte das Gerät nur so, wiein diesem Handbuchangegeben. Um Feuer oder Verletzungen zu vermeiden, verwenden Sie ein ordnungsgemäßes Netzkabel.
Page 8
Wenn Sie am Gerät einen Defekt vermuten, sorgen Sie dafür, bevor Sie das Gerät wieder betreiben, dass eine Untersuchung durch RIGOL autorisiertem Personal durchgeführt wird. Jedwede Wartung, Einstellarbeiten oder Austausch von Teilen am Gerät, sowie am Zubehör dürfen nur von RIGOL autorisiertem Personal durchgeführt werden. Belüftung sicherstellen.
RIGOL Sicherheits Begriffe und Symbole Begriffe in diesem Guide. Diese Begriffe können in diesem Handbuch auftauchen: WARNING Die Kennzeichnung WARNING beschreibt Gefahrenquellen die leibliche Schäden oder den Tod von Personen zur Folge haben können. CAUTION Die Kennzeichnung Caution (Vorsicht) beschreibt Gefahrenquellen die Schäden am Gerät hervorrufen können.
50 MHz User Manuals of this Product: The user manuals of this product include the Quick Guide, User’s Guide, Programming Guide, Data sheet and etc. For the latest version of the desired manual, download it from www.rigol.com. VIII MSO1000Z/DS1000Z Service Guide...
Contents RIGOL Contents Guaranty and Declaration ................. I Safety Requirement ................II General Safety Summary ................II Safety Terms and Symbols ............... IV Allgemeine Sicherheits Informationen ............V Sicherheits Begriffe und Symbole ............. VII Document Overview ................VIII Chapter 1 Disassemble and Assemble ..........
Chapter 1 Disassemble and Assemble RIGOL Chapter 1 Disassemble and Assemble Disassemble and Assemble Notices Notices: Do not disassemble the instrument unless for working requirement. Only authorized personnel can disassemble the instrument. Cut off the power supply before disassembling the instrument.
RIGOL Chapter 1 Disassemble and Assemble Exploded View of the Device You need to get a basic understanding of the main parts of the instrument before disassembling and assembling the instrument. When disassembling or assembling the instrument, please follow the procedures and avoid scratching the part surface.
Page 15
Chapter 1 Disassemble and Assemble RIGOL Table 1-1 Part Explanation of MSO1000Z/DS1000Z Exploded View Part Name Part Name ○ ○ Front Panel Power Shield ○ ○ Large Knob Power Supply Board ○ ○ Small Knob Rear Foot ○ ○ Rear Cover ○...
RIGOL Chapter 1 Disassemble and Assemble To Disassemble the Rear Cover Handle Rear Cover ② ② ① Figure 1-2 To Disassemble the Rear Cover Part Explanations: ① 2 screws (one on each side, torx pan head screw M3*10) at the handle groove.
Chapter 1 Disassemble and Assemble RIGOL To Disassemble the Rear Metal Cover ① ① ① ① ① ① ① Rear Metal Cover BNC Washer BNC Nut Figure 1-3 To Disassemble the Rear Metal Cover Part Explanation: ① 11 screws (torx countersunk head screw M3*6) fixing the front metal plate and rear metal cover (the positions of some of the screws are not marked out in the figure above and please disassemble them according to their actual positions).
Page 18
RIGOL Chapter 1 Disassemble and Assemble Tip: Pay attention to the connecting positions of the power cord and fan cable before removing them to avoid incorrect connection or incomplete connection when assembling the instrument. Check whether the screen line and the keyboard cable on the main board are ...
Chapter 1 Disassemble and Assemble RIGOL To Disassemble the Knobs ① ① ① ① ① ① Figure 1-4 To Disassemble the Knobs Part Explanation: ① 6 knobs Disassemble Step: Disassemble the 6 knobs (①). Tip: It is recommended that you use a lever-like tool to pry out the knob when disassembling the knob and place a soft pad at the force bearing point to avoid damaging the key film and knob.
RIGOL Chapter 1 Disassemble and Assemble To Disassemble the Front Panel ① ① ① ① ① ① ① Figure 1-5 To Disassemble the Front Panel Part Explanation: ① 7 screws (torx countersunk head self tapping screw M3*8) fixing the front panel.
Chapter 1 Disassemble and Assemble RIGOL To Disassemble the Keyboards, LCD and Digital Channel Input Port ③ ① ③ Left ② Keyboard ② ③ ② ① ③ Main Keyboard ④ ② ④ BNC Washer ② BNC Nut Figure 1-6 To Disassemble the Keyboards, LCD and Digital Channel Input Port Part Explanations: ①...
Page 22
RIGOL Chapter 1 Disassemble and Assemble Tip: Pay attention to the connecting positions of the keyboard cables and screen line connected to the main board before removing them to avoid incorrect connection or incomplete connection when assembling the instrument.
Chapter 1 Disassemble and Assemble RIGOL To Disassemble the Main Board ① ① ① ① ② ③ ⑤ Signal Source Board ④ Signal Source Shield Cover Output Board Figure 1-7 To Disassemble the Main Board (take MSO1000Z-S as an example) 1.
Page 24
RIGOL Chapter 1 Disassemble and Assemble and take off the shield cover gently. (4) Remove the screw (③) fixing the signal source board using the 5mm hexagon socket, and take off the signal source board gently. (5) Remove the screw (②) fixing the main board and front metal plate using the 5mm hexagon socket.
Chapter 1 Disassemble and Assemble RIGOL Assemble Procedures The assemble procedures are the reverse of the disassemble procedures. Check whether the cables are correctly connected and whether all the screws are installed after each step of assemble. You are recommended to follow the order and methods introduced above when disassembling and assembling the instrument to avoid damage to the instrument due to improper operation and to save your time.
The commonly encountered failures and their solutions are listed below. When you encounter those problems, please solve them following the corresponding steps. If the problem remains still, please contact RIGOL and provide your device information (acquisition method: Utility System System Info).
Page 28
RIGOL Chapter 2 Troubleshooting&Maintenance Note: Using AUTO could automatically finish the above setting. 6. The display of waveform is ladder-like: (1) The horizontal time base might be too low. Increase the horizontal time base to increase the horizontal resolution and improve the display.
To get repair service, please contact with your nearest RIGOL sales and service office. RIGOL does not provide other warranty items except the one being provided by this warranty statement. The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose.
RIGOL Chapter 2 Troubleshooting&Maintenance General Care and Cleaning General Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time. Cleaning Clean the instrument regularly according to its operating conditions. To clean the exterior surface, perform the following steps: Disconnect the instrument from all power sources.