Foreword
Trucks for use in zone 1 are automatically
approved for use in zone 2. Depending on the
zone classification, the trucks' operating and
display elements may be enclosed in a special
housing. Gases and vapours are divided into
temperature classes T1 to T6 and permissible
equipment surface temperatures are defined.
Temperature classes
Temperature
class
T1
T2
T3
T4
T5
T6
.

Commissioning

Commissioning is the initial intended use of
the truck.
The necessary steps for the commissioning
vary depending on the model and equipment
of the truck. These steps require preparatory
work and adjustment work that cannot be per-
formed by the operating company. See also
the chapter entitled "Definition of responsible
persons".
– To commission the truck, contact the
authorised service centre.

Proper use

The truck described in these operating in-
structions is suitable for lifting, transporting
and stacking loads.
The truck may only be used for its proper
purpose as set out and described in these
operating instructions.
The industrial truck may only be used in
the areas at risk of explosion for which it is
Ignition temperature range
> 450°C
> 300°C to 450°C
> 200°C to 300°C
> 135°C to 200°C
> 100°C to 135°C
> 85°C to 100°C
56368011531 EN - 06/2019 - 02
Using the truck
Maximum surface temperature
450°C
300°C
200°C
135°C
100°C
85°C
1
21