4
Handling the battery
Checking the battery condition, acid
level and acid density
WARNING
The electrolyte (diluted sulphuric acid)
is poisonous and corrosive!
– Observe the safety regulations
for handling battery acid; see the
chapter entitled "Battery acid".
– Wear personal protective equip-
ment (rubber gloves, apron and
protection goggles).
– Rinse away spilt battery acid
immediately using plenty of water.
CAUTION
Improper handling of batteries can cause damage!
A competent person must check that the battery is
in proper condition.
The tray cover interlock and connection assemblies
must close properly. It must only be possible to
open them using tools. (Category-2 version)
The reverse polarity protection of the battery male
connectors must be checked.
– Observe the information in the operating instruc-
tions for the battery.
– Ensure that the battery tray is closed correctly all
the way round.
– Ensure that a tray lid is present for category-2
versions.
– Only use batteries and plug connectors that are
approved for potentially explosive areas and for
the truck.
The safety officer will allocate a safe place
where the following work can be performed.
– Remove the battery from the truck.
– Open the battery tray cover. (Category-2
version)
– Check any ventilation openings for damage.
– Check the coating of the battery tray and the
tray cover for damage.
– Check the battery for any cracks in the
housing, raised plates and acid leaks.
– Check the battery male connectors.
– Check cable inlets for damage.