Testing Hydraulic Bucket Tappets - Skoda OCTAVIA MK1 Service Manual

Drive unit
Table of Contents

Advertisement

Install bearing caps
5, 1 and 3 and also
tighten to 20 Nm.
Set the Woodruff key
in the camshaft.
Install camshaft
sprocket and tighten
to 100 Nm (use
counterholder -MP 1-
216-).
Installing and
tensioning toothed
belt (setting timing)
Chapter.
Note
After installing the
camsaft, the engine
must not be started
for about 30
minutes. The
t
hydraulic clearance
compensation
elements must settle
(otherwise valves
would strike the
pistons).
After carrying out
work on the valve
gear, carefully crank
engine at least 2
t
revolutions to ensure
that no valve
touches the piston
when the engine is
started.

Testing hydraulic bucket tappets

Special tools and workshop equipment required
t
Feeler gauge
t
Wooden or plastic wedge
76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents