t Remote control -V.A.G 1348/3A - with adapter cable -V.A.G 1348/3-2 -
t
Adapter -V.A.G 1318/17-
t
Measuring vessel
Test conditions
l
Battery voltage at least 12 volts
l
Voltage supply o.k.
l
Fuel filter o.k.
Test sequence
–
Switch off ignition.
– Connect remote control -V.A.G 1348/- 3A with adapter cable -V.A.G 1348/3-2-
–
Remove fuel filler cap from fuel filler neck.
WARNING
The fuel system is under pressure! Before opening the system lay cleaning cloths around the
connection point. Reduce pressure by carefully releasing the connection point.
Detach fuel return-flow line -2- (press
–
release button).
Connect auxiliary hose to adapter
–
-V.A.G 1318/17 - and fit onto fuel return
line from engine and hold in a measuring
vessel.
Operate remote control for 15 seconds
–
(press and hold button).
116
→