Test sequence
Connect vehicle system tester -V.A.G 1552- and select address word 01 "Engine
electronics". Engine idling.
Select 08 for the function "read measured value block" and further select display group
019.
Observe display value in the display field 4. (3rd position from
right).
Specified value: x x x x x 1 x x
Depress the clutch pedal and observe the display value in the
display field 4.
Specified value: x x x x x 0 x x
End the test using the function 06 "End output".
If the specified value is not reached:
Connect the test box -V.A.G 1598/22 - to the wiring loom of the
engine control unit
Check wiring between the test box and the 2-pin plug for
continuity according to the current flow diagram.
Contact 2+bush 21
Cable resistance max. 1.5 Ω.
If the specified value is reached:
Check the cables between the 2-pin plug contact 1 and the fuse
34 for interruption according to the current flow diagram. Cable
resistance: max. 1.5 Ω
locations
Chapter.
→ Current flow diagrams and Fitting
257
Reading measured value
block 19
->
850/rpm
0
00000100
1