Skoda OCTAVIA MK1 Service Manual page 260

Drive unit
Table of Contents

Advertisement

Unlock plug connection and remove from
ABS control unit.
Check CAN databus cables for short
circuiting with each other:
Measure resistance between test box
sockets 29 and 31.
Specified value: ∞ Ω.
If the specified value is not reached (there
is a short-circuit between the cables):
Eliminate the fault in the wiring
according to the current flow diagram
→ Current flow diagrams and Fitting
locations.
If the specified value is reached (there is
no short-circuit between the cables):
Connect test box -V.A.G 1598/21 --1- to
wiring loom of the ABS control unit -2-.
Check CAN databus cables between the
test box bushes 1598/22 and 1598/21 for
interruption according to the current flow
diagram: cable resistance: max. 1.5 Ω.
Bush to test box 1598/22
Additionally check the cable for a short circuit to positive and/or to earth.
If no fault is found:
Replace ABS control unit:
If the measured value corresponds to the specified value:
Remove air filter:
– Unlock plug connection and remove from
29
31
→ Chassis → Rep.
Bush to test box 1598/21
Gr.45.
260
10
11

Hide quick links: