Skoda OCTAVIA MK1 Service Manual page 201

Drive unit
Table of Contents

Advertisement

Perform resistance measurement
between the contacts of the valve with
multimeter.
Specified value: approx. 14.5 Ω.
If the engine is warm the resistance
increases by approximately 4 to 6 Ω.
If the nominal value is not reached,
replace the injection valve.
B - Checking voltage supply
Test conditions
l Fuel pump relay o.k., test
Fuse for injection valves O.K.
l
flow diagrams and Fitting locations
Disconnect plug at the injection valve to
be tested.
Connect the voltage tester between
contact 1 of the plug and the engine
mass.
Note
So that the engine does not start,
disconnect the plug at the ignition module.
Operate starter for some seconds, the
voltage tester must light up.
If the voltage tester does not light up,
check the continuity of the wiring from
contact 1 to fuse for injection valves and
if necessary eliminate open circuit
→ Current flow diagrams and Fitting
locations.
If the voltage tester lights up, test
actuation of the injection valves.
C - Test actuation of the injector valves
Disconnect plug at the injection valve to
be tested.
→ Chapter
→ Current
201