Skoda OCTAVIA MK1 Service Manual page 175

Drive unit
Table of Contents

Advertisement

1
1 Air conditioning compressor on
Display group 020 (operating state of lambda control, see also display group 099):
l
Engine runs in idling speed
Reading measured value
block 20
xxx rpm xxx mg/s xxx °C xxxxx
1
2
Idling speed
1)
On the points marked with "X", a "0" or a "1" can be optionally displayed.
Note
t
Re display field 4:
Meaning of the digits in the 8-digit numerical block for the operating condition of the
t
lambda regulator:
x x x x x x x x
1
Diagnostic fault entered in the fault memory; interrogate fault memory
0
not assigned
0
not assigned
1
limited dynamics active
1
Lambda controller on stop
Power-assisted steering pressure switch active
← Readout on display
xxx
3
4
← Display fields
Operating condition of lambda
controller
Coolant temperature
drawn in air mass
Meaning, if display positions = 1
→ Note
175
Specificati
Analysis
on
0001011X
→ Ancho
r
80...110
→ Chapt
°C
er
76...164
→ Chapt
mg/s
er
-
→ Chapt
er
→ Chapter