SPX RADIODETECTION 6100-Cu Operation Manual page 95

Multifunction phone network analyser and copper tester
Hide thumbs Also See for RADIODETECTION 6100-Cu:
Table of Contents

Advertisement

o
Cancel button closes the hookup
diagram prompt only.
The Confirmation window is prompted before
every NEXT test is started if you selected Yes
for the Show hookup diagram. You can select
No to hide the diagram next time you run the
test.
However, you can check the connection
diagram at any time by pressing the Hookup
Diagram button. In this case, the test does not
start when you press the OK button to close
the Confirmation window.
Threshold Settings button opens a new page
that allows you to set the NEXT Spectrum
Threshold.
Select Graph button changes to Graph
Selected when pressed and opens a new
selection of function keys which allow you to
maneuver the graph as follows:
o
Cursor - press the left/right arrow keys
to decrease/increase the values by
moving the cursor. Press and hold the
left/right arrow keys to accelerate the
cursor. Press
and place it in the middle of the current
x-axis limits.
o
Zoom references the middle of the x/y
axis and not the cursor position. Press
the arrow keys as follows:
© 2020 Radiodetection Ltd
to recall the cursor
6100-Cu Multifunction Copper Tester Operation Manual
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.
o
Pan - use left/right arrow keys to pan the
x-axis and the up/down arrow keys to
pan the y-axis.
o
1:1 resets the x-axis and y-axis limits to
full scale.
o
Return To Test removes these function
keys and displays the Spectrum page.
Result displays the pass/fail status, and test
results in graphical format.
Good is the good threshold value for the
selected bandwidth, represented by a
horizontal green line.
Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options.
4. Press
to confirm the value.
Spectrum Threshold Settings
The Threshold Settings page allows you to set the
Crosstalk threshold values at fixed and periodic
frequencies.
Type is the threshold limit: either Maximum or
Minimum.
Enabled is a flag to use the existing threshold:
either Yes or No. For example, setting the
threshold Enabled to No will disable pass/fail
threshold.
95

Advertisement

Table of Contents
loading

Table of Contents