6100-Cu Multifunction Copper Tester Operation Manual
some cases, a TDR may reflect off such a fault but then
again, may not. Try TDR first, but be prepared to try
RFL if you really need this pair in service for a high-
speed broadband.
To select either TDR or RFL tests:
1. Press
to return to the Copper Main menu.
2. Highlight TDR or RFL and press
the test.
Snapshot
The resistance Snapshot shows measured resistance
values in Ohms and cable lengths for each lead
combination. The parameters are as follows:
Current Group is the current test group name,
for example Multimeter.
Current Test displays the test being
measured. When FED is Enabled, the FED
icon and numeric state are displayed beside
the Current Test. Here you can switch to
another test from the given list. However, this
action will terminate the ongoing measurement
test.
Selected Pair allows you to select All Pairs or
a single wire pair for measurement.
Cable Parameters:
o
Cable Type displays the ID, Cable
Name and Fill, and allows you to select
an entry (with its associated
parameters) from the current Cable
Book, to use for testing. The selection
is not saved when leaving the test. The
current Cable Book entry is shown by
default.
60
Resistance displays the resistance per length
constant of the selected Cable Type. The
value is updated when Cable
Temperature/Type is changed.
Threshold Settings button opens a new page
to launch
that allows you to set resistance thresholds for
each pair.
Result displays a snapshot of the pass/fail
status, Resistance and Length for each
selected wire pair.
Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
options.
4. Press
Resistance Thresholds
The Resistance Threshold Settings page allows you
to set the Resistance for each pair. The threshold is a
programmable value you can use as an on-screen
indicator in each test when a measured value is too
high or too low.
o
Cable Temperature is the temperature
in either °F or °C of the cable under
test.
on a value to open a list box of
to confirm the value.