6100-Cu Multifunction Copper Tester Operation Manual
Cable Type # displays the number of a cable
section set above, ID, Cable Name and Fill,
and allows you to select an entry (with its
associated parameters) from the current Cable
Book, to use for testing.
For each section, the selected Cable Type
must have attenuation data available or else
the total equivalent attenuation cannot be
calculated. The selection is not saved when
leaving the test. The current Cable Book entry
is shown by default.
Section Length specifies the cable length of
each section. The total length for all cable
sections cannot exceed 8000 m or 24000 ft. If
you do not enter a length for each section
selected, the total equivalent attenuation
cannot be calculated.
Cable Attenuation Data is set to Yes for each
cable section selected.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
WB Attenuation Result Details
The Results Details read-only page displays the Cable
Length, pass/fail status, and WB Attenuation test
results in text and graphical format.
Test Group is the overall test group of the
selected saved results file, for example
Frequency Tests.
Test Identification is the test type of the
group, for example WB Attenuation.
Test Modes is the mode of test, for example
Attenuation.
Threshold Frequency displays the technology
used for threshold pass/fail estimation.
Cable Configuration button opens a new
page displaying the cable parameters of the
test. Use the left/right arrows to select the
button and press
106
to open the page.
Select Graph button changes to Graph
Selected when pressed and opens a new
selection of function keys which allow you to
maneuver the graph as follows:
o
Cursor - press the left/right arrow keys
to decrease/increase the values by
moving the cursor. Press and hold the
left/right arrow keys to accelerate the
cursor. Press
place it in the middle of the current x-axis
limits.
o
Zoom references the middle of the x/y
axis and not the cursor position. Press
the arrow keys as follows:
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.
o
Pan - use left/right arrow keys to pan the
x-axis and the up/down arrow keys to
pan the y-axis.
o
1:1 resets the x-axis and y-axis limits to
full scale.
o
Return To Results removes these
function keys and displays the
Attenuation results page.
When Mask was enabled for the selected
bandwidth:
The end of tolerance or fail point may be
displayed as a red cursor value.
Good is the good balance threshold mask for
the currently selected bandwidth, represented
by green in the graph.
to recall the cursor and