6100-Cu Multifunction Copper Tester Operation Manual
To change the order:
1. Press
to get into the list.
2. Use the up/down arrow keys to select the
desired entry.
3. Press
to come out of the list.
4. Press the up or down arrow key to activate the
Up/Down buttons.
5. Using the left/right arrow keys, select Up/Down
and press
to move the entry up/down the
list.
6. Press
to go back to the File Name tab.
The File Name Preview will be updated with
your changes.
Buzzer
The Buzzer is a built-in, continuous warning system to
detect hazardous voltage levels on the line/test leads.
The tab allows you to configure values for the buzzer
settings. However, due to the risk of electrical shocks,
the 6100-Cu detects high voltages on any pair of leads
without user intervention.
42
Buzzer Threshold Voltage allows you to
configure the hazardous voltage level from 70
to 150 volts.
Hush Time allows you to configure the hush
timeout from 1 to 15 minutes.
Hush Buzzer button mutes the sounding
buzzer.
Note: When the 6100-Cu raises the hazardous voltage
flag, it opens the relays and you will have to
press Start/Stop on the keypad to re initialize the
unit. In case the voltage is still too high, the
6100-Cu will open the relays once again
preventing any damage to the equipment. If not,
the test will start normally.
To set the buzzer settings:
1. Use the up/down arrow keys to select the
desired parameter.
2. Press
on an entry to open the
alphanumeric editor screen and use the
navigation keys to scroll through.
3. Press
to confirm each value.

7.8 Test Lead Compensation

Test Lead Compensation should be performed when
copper test accuracy is in question, since test lead
characteristics have some impact on copper test results
(mainly resistance, capacitance, and TDR tests). Test
lead characteristics vary with respect to cable
temperature.