Select Cable
The Select Cable page lists entries by ID, Cable
Name, and Cable Fill. The list can display a maximum
of 25 entries. Only the cables from the selected Cable
Book will be available for selection in test screens.
Also, only cables from the CableBookSettings can be
edited or deleted.
Select Custom Cable Book
o
FactoryDefaultBook
o
CableBookSettings
o
ItalianCableBook
o
UKCableBook
o
FranceCableBook
o
Cable # in Use displays the ID number
of the cable in use.
o
Cable Book Version displays the
current edition number of the Cable
Book in use.
To select a cable in use:
1. Press the up/down arrow keys to highlight the
desired entry and press
Use is updated with the current selection
displaying Cable Details.
OR
2. Press
to cancel your selection and go
back to the Cable Book menu.
Cable Details
The Cable Details page allows you to view the
parameter details of the Cable # in Use, or select a
© 2020 Radiodetection Ltd
6100-Cu Multifunction Copper Tester Operation Manual
Cable ID number by pressing the left/right arrow keys
on the keypad and view its details. You can only modify
cables from the CableBookSettings book, see above.
. The Cable # in
Cable Name is the name of the cable in the
Cable Book.
Cable Gauge is the gauge system for
measuring wire sizes in AWG (American Wire
Gauge) units or mm (metric wire size).
Cable Fill is the type of material the cable is
filled with: Aircore, Jelly, Pulp, 5 PR, or 2 PR.
Capacitance T-R/A-B specifies a value for the
capacitance per length constant.
Capacitance T/R to GND/A/B to E specifies a
value for the capacitance per length to ground
constant.
Resistance specifies a value for the resistance
constant of the cable.
Attenuation @ 300 kHz specifies a value for
the reduction in signal strength or insertion loss
of the cable.
VOP Ratio is the velocity of propagation for the
cable as a ratio of the speed of light
VOP Percentage is the velocity of propagation
for the cable as a percentage of the speed of
light
VOP V/2 m/µs is the velocity of propagation for
the cable in m/µs divided by 2
Temperature specifies the temperature of
reference at which all cable parameters have
been measured, in either ⁰F (Fahrenheit) or ⁰C
(Celsius) units. The measurement units are
updated based on the Temperature settings in
Setup/Application Settings/Standard.