SPX RADIODETECTION 6100-Cu Operation Manual page 119

Multifunction phone network analyser and copper tester
Hide thumbs Also See for RADIODETECTION 6100-Cu:
Table of Contents

Advertisement

way, you do not have to tweak the gain just to
see events at the far end.
Select from 4 possible entries:
o
Disabled
o
Enabled
o
Disabled with Auto Scale
o
Enabled with Auto Scale
Use Auto Scale to easily capture and see the
detected Largest Event applying automatic
scaling of the amplitude of the trace in the
vertical axis.
Pulse Width is a non-editable value in Auto
TDR but can be selected from a given list in
Manual and xTalk TDR.
Dual Trace Offset % is a configurable offset
parameter for the secondary trace, with a
range of -100 % to +100 %.
Note: If the loaded secondary trace offset = 0, then the
primary and secondary traces will overlap.
VOP allows you to change the velocity of
propagation value for the cable.
Current Trace (available only in Manual TDR)
allows you to turn on/off Live and Peak traces
and calculates the Differential trace. Select
one of the following:
o
Live turns Peak Hold off clearing
previously collected minimum/maximum
measurement values. This is the default.
o
Live and Peak turns Peak Hold on and
collects minimum/maximum
measurement values, displaying all 3
traces.
o
Peak Only turns Peak Hold on
displaying only Peak traces with no
offset.
o
Live+Store+Diff selection is only
available while the test is running and a
Trace is loaded. The differential trace is
calculated between Live and loaded
stored traces during the measurement,
and displayed on the graph with no
offset.
© 2020 Radiodetection Ltd
6100-Cu Multifunction Copper Tester Operation Manual
o
Differential Only selection is only
available while the test is running and a
Trace is loaded. Only the calculated
differential is displayed on the graph.
Cable Setup button opens a new page that
allows you to set the Cable Parameters for the
Current Test.
Select Graph button changes to Graph
Selected when pressed and opens a new
selection of function keys which allow you to
maneuver the graph as follows:
o
Cursor/Marker allows you to select the
cursor (blue) or marker (red)
independently by toggling the function
key. The footer updates to reflect either
Move cursor or Move marker.
Press the left/right arrow keys to
decrease/increase the values by moving
the cursor/marker. Press and hold the
left/right arrow keys to accelerate the
cursor/marker. Press
cursor/marker and place it in the middle
of the current x-axis limits.
o
Zoom references the middle of the x/y
axis and not the cursor position. Press
the arrow keys as follows:
Right = x-axis zoom in.
Left = x-axis zoom out.
Up = y-axis zoom in.
Down = y-axis zoom out.
o
Pan - use left/right arrow keys to pan the
x-axis and the up/down arrow keys to
pan the y-axis.
o
1:1 resets the x-axis and y-axis limits to
full scale.
to recall the