Rx Tone With Fed - SPX RADIODETECTION 6100-Cu Operation Manual

Multifunction phone network analyser and copper tester
Hide thumbs Also See for RADIODETECTION 6100-Cu:
Table of Contents

Advertisement

6100-Cu Multifunction Copper Tester Operation Manual
Current Test displays the test being
measured. Here you can switch to another
frequency test from the given list. However, this
action will terminate the ongoing measurement
test.
Receive Tone allows you to select either a VF
(voice frequency) or WB (wideband) signal.
Termination Resistance lists a resistance
value for the termination of the Receive Tone.
Result displays the values for both the RX
VF/WB Level and VF/WB Frequency.
Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
Result Details
The Results Details read-only page displays the saved
receive tone or RX VF/WB Level and VF/WB
Frequency values.
114
Profile Details Receive Tone
The Profile Details page displays read-only Receive
Tone Test Parameters.
Tone displays whether the receive tone was
VF or WB.
Termination Resistance is the resistance
value selected for the termination of the
Receive Tone test.

12.9 RX Tone with FED

The RX Tone with FED test can be setup to run a
single frequency or run sequentially through a selected
number of frequencies. The Teletech TS125 or Viavi
UFED IIB Remote FED (far end device) is used and
FED software option must be enabled on your unit.
However, the test is not dependent on enabling the
FED in FED Setup.
Single Tone