SPX RADIODETECTION 6100-Cu Operation Manual page 94

Multifunction phone network analyser and copper tester
Hide thumbs Also See for RADIODETECTION 6100-Cu:
Table of Contents

Advertisement

6100-Cu Multifunction Copper Tester Operation Manual
To set threshold values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
Spot Result Details
The Spot Results Details read-only page displays the
saved pass/fail status, NEXT and Frequency (TX)
values.
94
Spectrum
Spectrum is a snapshot mode of operation similar to
WB Attenuation. The test makes one measurement of
the crosstalk for the selected bandwidth, and then
stops.
Current Group is the current test group name,
for example Noise Tests.
Current Test displays the test being
measured. Here you can switch to another
Noise test from the given list. However, this
action will terminate the ongoing measurement
test.
Bandwidth allows you to select the bandwidth
of the frequency range for the test. Available
frequency bandwidths are: 2.2 MHz, 8 MHz, 12
MHz, 17.6 MHz and 30 MHz.
Termination Resistance lists a choice of
resistance values for the termination of the
signal.
Show hookup diagram on test setup - If Yes,
the Confirmation page is prompted before
every NEXT test is started. Select No to hide
the diagram next time you run the test.
Hookup Diagram button opens a
Confirmation page displaying how to connect
your cables at the beginning of the test. When
FED is Enabled on the FED Setup page, both
the T-R/A-B and T1-R1/A1-B1 pairs will be
terminated at the FED. The hookup diagram
uses graphic and textual components.
o
Proceed button closes the hookup
diagram prompt and starts the test.
© 2020 Radiodetection Ltd