To access Pair Detective from Multimeter tests:
1. Press
to return to the Copper Main menu.
2. Highlight Pair Detective and press
launch the test.
See
TDR
on page 117 for more help on using this test.
The Snapshot page shows measured Capacitance
values and Length for each lead combination. The
parameters are as follows:
Current Group is the current test group name,
for example Multimeter.
Current Test displays the test being
measured. When FED is Enabled, the FED
icon and numeric state are displayed beside
the Current Test. Here you can switch to
another test from the given list. However, this
action will terminate the ongoing measurement
test.
Note: The accuracy of the 2 Terminal Capacitance
Measurement is impacted by the use of the
FED, and the 3 Terminal (default) method is
recommended to be used instead.
Selected Pair allows you to select All Pairs or
a single wire pair for measurement.
Cable Parameters:
o
Cable Type displays the ID, Cable
Name and Fill, and allows you to select
an entry (with its associated
parameters) from the current Cable
Book, to use for testing. The selection
is not saved when leaving the test. The
current Cable Book entry is shown by
default.
o
Capacitance T-R/A-B displays the
capacitance value from Tip to Ring in
66
to
Threshold Settings button opens a new page
that allows you to set the capacitance balance
threshold for the test.
Result displays a snapshot of the pass/fail
status, Capacitance and Length for each
selected wire pair. Capacitive Balance is
shown in % when All Pairs are selected.
Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
options and use the navigation keys to scroll
through.
4. Press
Continuous
The Continuous function measures each pair,
displaying and updating results in real time, until you
stop the test. The last valid results then remain
displayed. Significant fluctuations in the capacitance
results/length could indicate intermittent or wet faults,
or a partial open.
nF/mi or km ranging from 10.0 to
500.0.
o
Capacitance T/R or A/B to GND/E
displays the capacitance value from
Tip or Ring to Ground, in nF/mi or km
ranging from 10.0 to 500.0.
on a value to open a list box of
to confirm the value.