6100-Cu Multifunction Copper Tester Operation Manual
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options.
4. Press
to confirm the value.
Current Thresholds
The AC/DC Current Threshold Settings page allows
you to set the Current threshold for each pair. The
threshold is a programmable value you can use as an
on-screen indicator in each test when a measured
value is too high or too low.
Type is the threshold limit for each pair: either
Maximum or Minimum.
Enabled is a flag to use the current threshold:
either Yes or No.
To set threshold values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
58
Continuous AC Page
The Continuous AC function measures each pair,
displaying and updating results in real time, until you
stop the test. The last valid results then remain
displayed. The Current test defaults to the
Continuous DC page from the Multimeter menu.
Continuous AC and Continuous DC are run
synchronously. Press Start/Stop on the keypad to run
the test.
Current Group is the current test group name,
for example Multimeter.
Current Test displays the test being
measured. Here you can switch to another test
from the given list. However, this action will
terminate the ongoing measurement test.
Selected Pair allows you to select All Pairs or
a single wire pair for measurement.
Termination Resistance is a read-only value
of 430 Ω that defines how much resistance the
tester uses to connect to the line.
Threshold Settings button opens a new page
that allows you to set the AC current thresholds
for each pair.
Result displays a snapshot of the pass/fail
status, AC current and frequency (Hz) results
for each selected wire pair.
Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR