6100-Cu Multifunction Copper Tester Operation Manual
o
Capacitance lists the units of
capacitance for Tip and Ring in nF/km
or nF/mi.
o
Resistance lists the units for
resistance in Ω/km or Ω/mi.
o
Attenuation lists the units for the
reduction in signal strength or insertion
loss of the cable, in dB/km or dB/mi.
o
Power Spectral Density (PSD) lists
the units to measure the noise energy
at a point in a noise spectrum. Units
are dependent on the previously
selected Level.
o
Cable Gauge Unit allows you to select
either AWG or mm wire gauge. AWG
is the default for ANSI and mm for ITU.
If you select AWG, only AWG cables
will be displayed in the Cable
Book\Select Cable list and test pages.
o
NTD (Network Terminal Device)
Provider allows you to filter out certain
devices in the Pair Detective test
dependent on your provider. None
(default) filters out all devices except
Short, Phone, and Phone Off Hook.
Disabled does not run the Device
Detection as part of Pair Detective test.
o
VOP allows you to select the velocity of
propagation for the cable as a Ratio,
Percentage, or V/2 m/μs (meters per
microsecond).
Label Customization
Connection lists the type of cable connection:
T-R-G or A-B-E.
Test Parameters Preset
o
Power Line Frequency lists the
frequency value of the power line.
o
Noise Filter lists the type of noise
filters to use.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options.
4. Press
to confirm the value.
40
Identification
The Identification tab allows you to preset values to
identify each single and auto test result file when
saving them. The parameters are as follows:
User Name/User ID allow you to enter up to 25
alphanumeric characters, in each field.
Contractor Name allows you to enter the
name of a contractor used to perform the tests.
Test From/To allows you to select from a list of
entries - up to 20 each, including user defined
values.
Test From/To List Setup buttons open
separate list management pages.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
Test List Setup
The Test From List Setup and Test To List Setup
pages allow you to manage the entries of the list.
However, there are 5 entries by default which cannot
be edited or deleted. These are DSLAM, NID, CPE,
CROSSBOX, and FRAME. When any of these are
selected, the Delete and Accept buttons are disabled.