6100-Cu Multifunction Copper Tester Operation Manual
FaultMapper Result Details
The Result Details read-only page displays the test
results in text and graphical format.
Test Identification is the name of the test, for
example FaultMapper.
Cable Setup button opens a new page
displaying the cable parameters of the test.
Use the left/right arrows to select the button
and press
to open the page.
Result displays the cable fault details.
Note: When running FaultMapper with a strap at the far
end of the pair, and there is a T-G/A-E fault, the
strap may also cause FaultMapper to display a
R-G/B-E short. In such cases, the resistance
shown is the resistance that would be measured
using a multimeter.
Estimated Length displays the cable length
when the cable is open.
Fault Status displays the number of faults
detected (or No fault detected) after running
the test.
80
Result Details Cable Setup
The Cable Setup page in the Result Details allows
you to view the Cable Parameters set for the
FaultMapper test.
Cable Type displays the ID, Cable Name and
Fill, (with its associated parameters) from the
current Cable Book, used for testing.
Cable Gauge identifies the gauge system for
measuring wire sizes, in AWG (American Wire
Gauge) units or mm (metric wire size).
Cable Fill is the type of material the cable is
filled with: Aircore, Jelly, Pulp, 5 PR, or 2 PR.
Capacitance T-R/A-B is the value for the
capacitance per length constant.
Capacitance T/R to GND/A/B to E is the value
for the capacitance per length to ground
constant.
Attenuation @ 300 kHz is the value for the
reduction in signal strength or insertion loss of
the cable.
Velocity of Propagation is the velocity of
propagation for the cable.
Resistance is the value for the resistance
constant of the cable.
Cable Length is the length of the cable set to
provide more accurate results.
Cable Temperature is the temperature of the
cable under test in either °F or °C.
FaultMapper Profile Details
The Profile Details page displays read-only
FaultMapper Test Parameters.