Tx/Rx Tone - SPX RADIODETECTION 6100-Cu Operation Manual

Multifunction phone network analyser and copper tester
Hide thumbs Also See for RADIODETECTION 6100-Cu:
Table of Contents

Advertisement

Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
3. OR
4. Press
on a value to open a list box of
options.
5. Press
to confirm the value.

12.8 TX/RX Tone

The TX/RX Tone tests allow you to generate tones and
measure the frequencies and levels of incoming
signals.
Send Tone
The Send Tone (TX) pane allows you to configure and
transmit a tone to a downstream device in the loop.
Current Group is the current test group name,
for example Frequency Tests.
Current Test displays the test being
measured. Here you can switch to another
frequency test from the given list. However, this
action will terminate the ongoing measurement
test.
Send Tone allows you to select either a VF
(voice frequency) or WB (wideband) signal (if
this option was purchased).
© 2020 Radiodetection Ltd
6100-Cu Multifunction Copper Tester Operation Manual
Level allows you to set the tone level value.
Level Step (read only) displays the level step
of the uplink frequency.
Frequency allows you to set a frequency value
for the transmitting tone.
Frequency Step lists a choice of frequency
step values.
Termination Resistance lists a resistance
value for the termination of the Send Tone.
Result displays the values for both the TX
VF/WB Level and VF/WB Frequency.
Test Status displays the current state of
measurement or an error message.
To select the parameter values:
1. Press the up/down arrow keys to highlight the
desired parameter.
2. Press the left/right arrow keys to view and
select the options.
OR
3. Press
on a value to open a list box of
options or the alphanumeric editor screen and
use the navigation keys to scroll through.
4. Press
to confirm the value.
Receive Tone
The Receive Tone (RX) tab allows you to configure
and run a receive tone test, which measures the
frequency and level of incoming signals.
Current Group is the current test group name,
for example Frequency Tests.