6100-Cu Multifunction Copper Tester Operation Manual
3. For T-R-G/A-B-E Shorted, connect the T-R-
G/A-B-E to the customer connectors (blue-
labeled Pair1- Cu) and the ground lead to the
network ground.
Note: P.U.T., in the above diagrams, refers to the Pair
Under Test.
The FED Control tab displays the following
parameters:
FED sets the default FED States to be
Disabled, Auto (automatic), or Manual for the
following tests. When Disabled/Auto, the
states are saved in the profile.
o
Multimeter
o
Noise
o
Frequency
o
Other
When FED is Auto or Manual and you start a
test, the 6100-Cu will warn you if the FED
battery level is low. Select OK to close the
message and run the test. Also, if the FED is
not present or not responding, a Confirmation
dialogue box will be displayed asking if you
want to disable FED and run the test anyway.
FED Type is enabled when FED is set to Auto
or Manual. If Auto is selected, you can choose
between TS125 or UFED IIB.
When UFED support is enabled:
o
the Isolation test voltage source will
automatically be limited to 125 V,
Return Loss test termination to 120 Ω,
and VF/WB Impulse Noise tests
duration to 15 min only.
44
o
MMT (maximum measurement time) is
determined for every test.
For tests which run in Continuous mode, the
MMT is set to 20 s allowing you to observe
continuous results in numerical or graphical
format.
At the end of the MMT, the continuous test is
terminated. However, due to UFED limitation,
the Continuous Isolation resistance test will
act the same as the test in Snapshot mode
and terminate after the Soak Time period
expires.
If Manual is selected, the FED Type is set to
TS125 by default. When FED is Manual, you
can set the FED to a desired state
independently from the one defined currently in
the FED setup for a particular test. This state
will be kept indefinitely until you set the FED to
another one, change the mode to Auto, or
disable the FED.
The Manual state of the FED Control is not
saved in the profile and is only kept for the time
of the current session. If you leave the copper
application, at next startup FED will be set to
the value saved in the profile: Disabled or
Auto.
Manual Setup includes 5 options:
o
Open 0
o
T-R/A-B Shorted 1
o
T-R-G/A-B-E Shorted 2
o
Pass Through/Exchange Connect 3
(default)
o
ID Tone 4
© 2020 Radiodetection Ltd